6 Installation
Caution!
DonotinstallDVS01panelinareawithpotentiallyammableorexplosivevapors.
1. Select panel location away from direct contact with water and oil.
2. Conrm clearance for wire connections behind wall, hull liner or bulkhead.
3. UsingDVS01paneltemplate(g.
7
, p. 11), cut out panel access hole and drill fastener holes.
4. Removepanelcover(g.
1
1,p.2)frommountingframe(3),ifnecessary,bycarefullypullingthem
apart. Install mounting frame to wall with four fasteners.
5. Withelectricalpoweroff,routeproperwiringtoDVS01panellocation,makingsurewiresextend
outthroughaccesshole(g.
1
4,p.2).Refertowiringdiagrams(gs.
4
and
5
, p. 3,
g.
6
, p. 4) for appropriate toilet system. Make nal wiring connections.
6. Push panel cover onto mounting frame until it locks.
7. TurnonelectricalpowertoDVS01panelandtoiletsystem.Conrmnormaloperationofstatus
lights.
7 Operation
7.1 Vacuum status monitor (g.
3
, p. 2)
1. WhenpowerswitchisturnedON,thegreen light indicates that there is sufcient vacuum in the
VacuFlushsystemtoushthetoilet(A).
2. WhenpowerswitchisturnedONandthered light glows, this indicates that there is NOT sufcient
vacuuminthesystemtoushthetoilet(B).Do not flush toilet, or blockage may occur in system.
Notes
Ifgreenandredlightconstantlycycleonandoffbetweenushes,thereisapossible
vacuumleakinthesystem.(AnidleVacuFlushsystemshouldnotcyclemorefrequently
than once every three hours.)
If green light is ON but there is no vacuum in system, a blockage has likely occurred
betweenthetoiletandvacuumtank.Openushballintoiletbowlandusestandardtoilet
plunger to unblock.
After a period of time, if red light seems to remain lit longer than when toilet system was
new,duckbillvalvesinvacuumpumpmayrequirereplacement.
Caution!
IfDVS01isconnectedtoa“fulltank”sensorandholdingtankisempty,acontinuousred
light may indicate extensive vacuum loss due to blockage, pump failure or leak. Turn off
vacuum system and repair as soon as possible.
7.2 “Full tank” monitor (whenconnectedto“fulltank”sensorinwasteholdingtank)
WhenpowerswitchisturnedON,theredlightglows,andthevacuumpumpisnotrunning,this
indicates that the holding tank is full and needs to be pumped out. Do not flush toilet, or blockage may
occur in system.